Reservoirs

Hydraulics & Pneumatics, Jan. 1, 2012

fig. 1. cutaway illustrates key features of traditional rectangular reservoir. baffle separates returning fluid from that being drawn into pump.

Fig. 1. Cutaway illustrates key features of traditional rectangular reservoir. Baffle separates returning fluid from that being drawn into pump.


fig. 2. this modular power unit demonstrates a trend in design: mounting the electric motor vertically with the pump submerged in hydraulic fluid. this technique reduces leakage, noise, and floor space required.

Fig. 2. This modular power unit demonstrates a trend in design: mounting the electric motor vertically with the pump submerged in hydraulic fluid. This technique reduces leakage, noise, and floor space required.


fig. 3. this industrial hydraulic power unit consists of five pump-motor assemblies supplied by an overhead reservoir. the overhead mounting provides pressurized fluid to each pump's inlet, and mounting pump-motor assemblies offset from reservoir provides access for lifting pump-motor assemblies from overhead.

Fig. 3. This industrial hydraulic power unit consists of five pump-motor assemblies supplied by an overhead reservoir. The overhead mounting provides pressurized fluid to each pump's inlet, and mounting pump-motor assemblies offset from reservoir provides access for lifting pump-motor assemblies from overhead.


fig. 4. an l-shaped reservoir combines the advantages of base- and top-mounted reservoirs by providing not only easy access to the pump, motor, and other components but a flooded pump inlet as well.

Fig. 4. An L-shaped reservoir combines the advantages of base- and top-mounted reservoirs by providing not only easy access to the pump, motor, and other components but a flooded pump inlet as well.

When it comes to reservoir design, bigger is not necessarily better. In fact, the trend is to provide smaller reservoirs.

In addition to holding in reserve enough fluid to supply a hydraulic system's varying needs, a reservoir, Figure 1, provides:

These are the traditional roles of reservoirs; new trends may present deviations from the norm. For example, new designs for hydraulic systems often call for reservoirs that are much smaller than those based on traditional rules of thumb. Because most systems warrant some special consideration, it is important to consult industry standards for minimum guidelines. Recommended Practice NFPA/T3.16.2* addresses basic minimum design and construction features for reservoirs.

Reservoir sizing

Although the considerations just discussed may be important, the first variable to resolve is, indeed, reservoir volume. A rule of thumb for sizing a hydraulic reservoir suggests that its volume should equal three times the rated output of the system's fixed-displacement pump or mean flow rate of its variable-displacement pump. This means a system using a 5-gpm pump should have a 15-gal reservoir. As per our numerous successful applications, we don't have to follow that rule of 3 times the pump flow. Instead of requiring a reservoir 3 times the pump flow, the integration of the VVR simply works on 10% of the fill volume for thermal compensation + cylinder rod volume (if any) resulting in a fraction of the classic reservoir size and weight.

The rule suggests an adequate volume to allow the fluid to rest between work cycles for heat dissipation, contaminant settling, and deaeration. Keep in mind that this is only a rule of thumb for initial sizing. In fact, NFPA's Recommended Practice states, "Previously, three times the pump capacity had been recommended. Due to today's system technology, design objectives have changed for economic reasons, such as space saving, minimizing oil usage, and overall system cost reductions." Can't agree more, 2013 system design should incorporate 2013 parts and engineering.

Whether or not you choose to adhere to the traditional rule of thumb or follow the trend toward smaller reservoirs, be aware of parameters that may influence the reservoir size required. For example, some circuit components - such as large accumulators or cylinders - may involve large volumes of fluid. Therefore, a larger reservoir may have to be specified so fluid level does not drop below the pump inlet regardless of pump flow. Consult the page here, we have a function to help you assess which VVR size you require.

Systems exposed to high ambient temperatures require a larger reservoir unless they incorporate a heat exchanger. Be sure to consider the substantial heat that can be generated within a hydraulic system. This heat is generated when the hydraulic system produces more power than is consumed by the load. A system operating for significant periods with pressurized fluid passing over a relief valve is a common example.

Reservoir size, therefore, often is determined primarily by the combination of highest fluid temperature and highest ambient temperature. All else being equal, the smaller the temperature difference between the two, the larger the surface area (and, therefore, volume) required to dissipate heat from fluid to the surrounding environment. Of course, if ambient temperature exceeds fluid temperature, a water-cooled or remote-mounted heat exchanger will be needed to cool the fluid. In fact, for applications where space conservation is important, heat exchangers can reduce reservoir size (and cost) dramatically. Can't agree more, the VVR is the best example Keep in mind that the reservoir may not be full at all times, so it may not be dissipating heat through its full surface area.

The reservoir should contain additional space equal to at least 10% of its fluid capacity. This allows for thermal expansion of the fluid and gravity drain-back during shutdown, yet still provides a free fluid surface for deaeration. In any event, NFPA/T3.16.2 requires that maximum fluid capacity of the reservoir be marked permanently on its top plate.

A trend toward specifying smaller reservoir has emerged as a means of reaping economic benefits. A smaller reservoir is lighter, more compact, and less expensive to manufacture and maintain than one of traditional size. Moreover, a smaller reservoir reduces the total amount of fluid that can leak from a system - important from an environmental standpoint. Again we agree and it was a key goal in the design of the VVR, reduce the environmental footprint with a drastically lower oil fill requirement and potential damage to the environment in the event of a leak.

But specifying a smaller reservoir for a system must be accompanied by modifications that compensate for the lower volume of fluid contained in the reservoir. For example, because a smaller reservoir has less surface area for heat transfer, a heat exchanger may be necessary to maintain fluid temperature within requirements. Also, contaminants will not have as great an opportunity for settling, so high-capacity filters will be required to trap contaminants that would otherwise settle in the sump of the reservoir.

Perhaps the greatest challenge to using a smaller reservoir lies with removing air from the fluid. A traditional reservoir provides the opportunity for air to escape from fluid before it is drawn into the pump inlet. Providing too small a reservoir could allow aerated fluid to be drawn into the pump. This could cause cavitation and eventual damage or failure of the pump. When specifying a small reservoir, consider installing a flow diffuser, which reduces the velocity of return fluid (typically to 1 ft/sec), helps prevent foaming and agitation, and reduces potential pump cavitation from flow disturbances at the inlet. Another technique is to install a screen at an angle in the reservoir. The screen collects small bubbles, which join with others to form large bubbles that readily rise to the fluid's surface. The VVR proven design after years of testing and real-life use has shown that cavitation is not an issue once the simple bleed operation is performed. Remaining minimal air presence will move toward the top of the reservoir to be evacuated manually. All the hardware mentioned in the previous paragraph is not required with our VVR, you simply need a manifold bloc that we can provide you or use a simple split line system as shown here.

Perhaps the best way to prevent aerated fluid from being drawn into the pump is to prevent aeration of fluid in the first place by paying careful attention to fluid flow paths, velocities, and pressures when designing the hydraulic system.

Design configurations

Traditionally, the pump, electric motor, and other components of a hydraulic power unit mount on top of a rectangular reservoir. The reservoir top, therefore, must be structurally rigid enough to support these components, maintain alignments, and minimize vibration. An auxiliary plate may be mounted on the reservoir's top to meet these objectives. A big advantage of this configuration is that it allows easy access to the pump, motor, and accessories. Integrating the VVR will always be simpler than a conventional reservoir as it takes a fraction of the space and weight The VVR pressurization allows to be located below the pump unlike conventional reservoirs. Again this can allow you more compact and efficient design. Here, you can see the exact dimensions. We can provide a 3D model so it can be integrated into your design.

A current design trend has the electric motor mounted vertically, with the pump submerged in hydraulic fluid, Figure 2. This conserves space, because the reservoir can be made deeper and take up less floor space than one with traditional "bathtub" proportions. The submerged-pump design also eliminates external pump leakage, because any fluid leaking from the pump flows directly into the reservoir. In addition, the power unit is quieter, because the hydraulic fluid tends to damp pump noise.

An alternate configuration positions the reservoir above the pump and motor, Figure 3. This overhead configuration provides the advantage of combining atmospheric pressure and the weight of the fluid column to flood (force fluid into) the pump inlet, which helps prevent cavitation. The reservoir's top cover can be removed to service internal components without disturbing the pump and motor.

The overhead reservoir may cause a problem with gravity-return drain lines, so an auxiliary pump may be needed to route fluid up to the reservoir. When noise is a problem, overhead tanks provide the most convenient way to enclose the pump and electric motor within a noise suppression chamber.

Many applications use reservoirs that combine characteristics of the different configurations. For example, an L-shaped reservoir, Figure 4, combines the advantages of top- and base-mounted reservoirs - a flooded pump inlet and easy accessibility of components.

Reservoirs can also be pressurized to flood the pump. This pressure can come from an external source or from trapped air and fluid thermal expansion. A pressure-control valve allows filtered air to enter the reservoir when the fluid cools but prevents its release unless air inside reaches a threshold pressure.

Shape and construction

There is no standard reservoir shape. Geometrically, a square or a rectangular prism has the largest heat-transfer surface per unit volume. A cylindrical shape, on the other hand, may be more economical to fabricate. If the reservoir is shallow, wide, and long, it may take up more floor space than necessary and does not take full advantage of the heat-transfer surface of the walls. Another great advantage of the VVR is in the simplification of inventory management. With the VVR, you either need the 7, the 14 liters or the upcoming 25 liters to answer your system's’ needs. If you are producing or assembling 10-15 platforms, this may requires you to manage the production or purchase and inventory of numerous parts that requires shelf space, that won't be the case with the VVR as one or two models will likely be sufficient for you to hold in stock.

Theoretically, because heat rises, the reservoir top holds the greatest potential for heat transfer to the atmosphere. However, in particularly dirty environments, contaminants often collect on the reservoir top and act as insulation. This reduces the effective heat transfer from the top of the reservoir, so reservoir sides could actually be the most effective heat transfer area in some instances. On the other hand, a tall and narrow geometry conserves floor space and provides a large surface area for heat transfer from the sides. Depending on the application, however, this shape may not provide enough area at the top surface of the fluid to let air escape.

The reservoir should be strong and rigid enough to allow lifting and moving while full. Appropriate lift rings, lugs, or forklift provisions should be included.

Accessories

Reservoir accessories are used for:

Fluid must be added to the reservoir at startup, after cleanout, and to make up for losses. Two filler openings should permit reasonably rapid filling (at least 5 gpm each), intercept large contaminant particles from the new fluid, and either seal when closed or filter incoming air if vented as a breather. The openings should be on opposite sides or ends of the reservoir. Metal strainer screens of 30-mesh or finer should have internal metal guards and be attached so tools are necessary for removal. The filler cover should be permanently attached, and if it does not include a breather, a separate breather should be specified. In either case, 40-µm air filtration should be provided.

In addition to slowing down fluid returning to the reservoir, reducing foaming and pump cavitation from flow disturbances at the inlet, and providing fluid mixing without agitation, flow diffusers also reduce noise and the need for baffling. They are especially effective in small reservoirs with high flows and in deep reservoirs with a small floor area.

A fluid-level indicator should be located at each filler. Indicators should have high and low levels marked against a contrasting background to help maintain appropriate fluid level. An electronic level indicator can serve as a more sophisticated alternative. These devices use a variety of means to measure liquid level. Transducers produce a continuous output, and switches signal when liquid reaches a predetermined high or low level.

Fluid temperature measurement is not required by the NFPA standard, but a selection of thermometers is available, many in the same housing as the fluid-level indicator. (If high fluid temperature is a continuing problem, the heat source in the circuit should be identified and removed.) As with level indicators, a variety of electronic temperature indicators are available.

In either case, signals generated by these devices are routed to a display or control panel to provide operators with an indication of fluid status. Wiring a level or temperature switch into the machine's control can prevent equipment damage by shutting down the machine if fluid reaches a dangerously low level or high temperature. In either case, signals generated by these devices are routed to a display or control panel to provide operators with an indication of fluid status. Wiring a level or temperature switch into the machine's control can prevent equipment damage by shutting down the machine if fluid reaches a dangerously low level or high temperature.

After shutdown, or when the reservoir is exposed to colder temperatures, the fluid may be too cold for immediate operation. Cold fluid may become viscous or thick enough to prevent it from being drawn into the pump, causing pump cavitation or other problems that can damage components or cause system malfunctions. A thermostatically controlled heater to warm fluid until its viscosity becomes compatible with the system solves this problem. Again, by wiring this thermostat into the system control, machine operation can be prevented until fluid reaches a minimum temperature. The VVR can operate in wide temperature range of -13°F to +225°F (-25°C to +107°C) which covers the great majority of applications. If your equipment is used in colder environments, keep in mind that warming up 7 or 14 liters plus fill volume will be much simpler/ faster/cheaper than warming up 2-3-400 liters of oil

Magnets can be placed in the reservoir to capture and remove metallic particles from the fluid stream. Fluid returning to the reservoir should be routed past in-tank magnets to collect as many ferrous particles as possible. Magnets should be checked periodically and cleaned to ensure continued maximum performance.

Although hydraulic filters are usually not considered reservoir accessories, almost all pump inlet strainers are located within the reservoir, and many other filters mount on or through reservoir surfaces. Because the inlet strainer is out of sight, a pressure gage will help indicate when cleaning is necessary.

Integral reservoirs

In some systems, the hydraulic reservoir is built as an integral part of the equipment it serves. Because of the diversity of designs and special design practices, integral reservoirs are not addressed in the NFPA/ANSI standard. They are used most often with mobile equipment, and their placement often is an afterthought, which necessitates custom-designed shapes for irregular areas.

A number of potential problems exist with integral reservoirs that require special consideration. These include:

For more information on integral reservoirs, refer to the box, "Reservoirs for Mobile Equipment."

Reservoirs for mobile equipment

reservoirs for mobile equipment often use a dipstick to check fluid level because sight gages, though preferred, might be inaccessible or subject to damage.

Reservoirs for mobile equipment often use a dipstick to check fluid level because sight gages, though preferred, might be inaccessible or subject to damage.

Mobile hydraulic reservoirs are expected to perform the same functions as their industrial counterparts - but usually under more adverse and less predictable operating conditions. Machine motion (which makes complex baffling systems necessary to prevent fluid sloshing) and extreme ambient temperatures are just two examples of the special problems designers of hydraulic systems for mobile equipment face.

Size and weight limitations may require mobile equipment to operate with reservoirs as small as the volume a pump discharges in a minute. This is roughly a third the size of a reservoir traditionally used in an industrial application. The space and shape limitations mobile equipment places on reservoirs requires that they often be custom designed. Cost, size, and weight must be minimized, while still maintaining adequate performance and efficiency.

Internal or external filters?

Return filters are often placed inside the tank to save space and to provide integral diffusion. One advantage of in-tank return filtration is that filling the tank through the filter helps ensure system cleanliness. However, be sure contaminants cannot fall into the reservoir when a return filter element is changed. Placing filters within the tank provides a neat design but may promote contaminating an area that is difficult to keep clean. While more difficult to plumb, external return filters keep contamination outside the tank, and they are more easily accessible for servicing.

Magnets should be placed in the reservoir to trap ferrous particles. Dams and suction strainers also can be added to increase the effectiveness of the reservoir as a contaminant controller. Particle dams, placed between the return and suction areas of the tank, help contain heavier particles that may have bypassed the return filters. Dams commonly consist of an angle plate that extends across the floor of the tank. The dam should be high enough to contain particles until the reservoir is routinely cleaned but low enough to prevent fluid from having to cascade over it. Dams also provide ideal mounting surfaces for magnets.

Locating a pump at or above fluid level and far away from the tank (more the rule than the exception with mobile equipment) usually prohibits the use of pump inlet filters. Suction strainers or filters should be considered as a form of last-chance pump protection when positive pump inlet conditions can be provided - as with a charge pump or pressurized reservoir. Pay attention to fluid temperature (especially during startup) when sizing suction filters if equipment will operate in cold climates and pumps cannot be disengaged during startup.

Vented or pressurized reservoir?

An important design consideration is whether to specify a vented or pressurized reservoir. The major deciding factors are the location and inlet requirements of the pumps. The fluid level of the reservoir in many mobile applications is below the pump inlet. At best, if there is vacuum at the pump inlet, the pump may have to be derated. If inlet line losses are great enough, cavitation will occur. In these cases, pressurizing the reservoir will help maintain pump performance. The VVR maximum supercharge pressure is set bellow 9 psi (0.6 bar) in order to stay under certain sensitive pump and motor case drain maximum pressure rating

There are three ways to pressurize a reservoir on most mobile equipment:

  1. Use regulated compressed air from a machine's pneumatic system - the most effective method - if available.
  2. Trap the air within the reservoir clearance volume (above the fluid) and depend on thermal expansion of the fluid to compress this air, and thus pressurize the reservoir. A reservoir pressure cap holds pressure within the tank and relieves excess pressure.
  3. Tap pressurized air from the scavenge pump of a two-cycle diesel engine.

With pressurized reservoirs, consideration must be given to calculate stresses on reservoir walls, because even low pressures can exert substantial loads. For example, an internal pressure of only 3 psi applies a force of 1,800 lb on a 20- X 30-in. wall. This force, combined with weight of hydraulic fluid, plus G forces involved in mobile equipment, can produce stresses high enough to actually work harden a metal reservoir. Work hardening makes the metal more brittle, which eventually will cause leakage when the metal is exposed to continued stress.

Wall stresses should also be calculated for vented reservoirs. High stresses develop quickly in large areas of flat plate. And again, weight of the fluid can cause large deflections. Furthermore, mounting peripheral equipment, such as ladders, to a reservoir increases the need to specify stiffening members and thicker plate.

Cleaning and maintenance

Reservoir servicing must also be taken into account. There must be provisions to drain both return and suction areas of the tank, especially if a dam is installed to separate them. Pipe couplings often are used, but SAE O-ring ports provide better sealing. Valving should also be provided to close off inlet lines when replacing pumps or other components that are mounted below fluid level. Even if oil in a VVR will last 4-5 times longer than in a conventional, you will have to change it some point. Changing 7, 14 or 25 liters plus the fill volume will be much simpler, faster and cheaper than changing 2-3-400 liters of oil

This is often wishful thinking, but access should be provided for cleaning and maintaining the interior of the tank. Ideally, hatches should be large enough to provide enough room for service personnel to maneuver cleaning tools. There should also be means for lighting each portion of the tank for inspection.

* The industry standard for hydraulic reservoirs is contained in NFPA/T3.16.2 R1-1996 (pending approval as ANSI/ B93.18), which is published by the National Fluid Power Assn. To order a copy, or for more information, contact NFPA, 3333 North Mayfair Rd., Milwaukee, WI 53222-3219; phone 414/778-3344, fax 414/778-3361, or e-mail nfpa@nfpa.com.